tmnxOamPmCfgTwampLtTxFrmsPerDelT
TIMETRA-OAM-PM-MIB ·
.1.3.6.1.4.1.6527.3.1.2.92.1.3.9.1.10
Object
column
r/w
frames Unsigned32
The value of tmnxOamPmCfgTwampLtTxFrmsPerDelT specifies the number of
TWAMP-Light frames to send in one MEF-35 'delta_t' (also known as
'Small Time Interval') when computing loss statistics for the
specified session's TWAMP-Light test.
The loss parameters used by SROS for TWAMP-Light tests (e.g.
tmnxOamPmCfgTwampLtTxFrmsPerDelT) are modelled after the MEF-35 loss
parameters defined for Synthetic Loss Measurement (SLM) tests. Hence,
the REFERENCE text for this object is a MEF-35 SLM section.
Expressed in milliseconds,
delta_t =
tmnxOamPmCfgTwampLtTxFrmsPerDelT *
tmnxOamPmCfgTwampLtInterval.
Context
- MIB
- TIMETRA-OAM-PM-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.92.1.3.9.1.10- Type
- column
- Access
- readwrite
- Status
- current
- Units
- frames
- Parent
- tmnxOamPmCfgTwampLtEntry
Syntax
frames Unsigned32
Values & Constraints
Object Constraints
range: 1-50