tmnxOamPmCfgTwampLtConsecDeltaTs
TIMETRA-OAM-PM-MIB ·
.1.3.6.1.4.1.6527.3.1.2.92.1.3.9.1.11
Object
column
r/w
Unsigned32
The value of tmnxOamPmCfgTwampLtConsecDeltaTs specifies the number of
consecutive MEF-35 'delta_t's (also known as 'Small Time Intervals')
which constitute a MEF-35 'Availability Window' when computing loss
statistics for the specified session's TWAMP-Light test.
The loss parameters used by SROS for TWAMP-Light tests (e.g.
tmnxOamPmCfgTwampLtConsecDeltaTs) are modelled after the MEF-35 loss
parameters defined for Synthetic Loss Measurement (SLM) tests. Hence,
the REFERENCE text for this object is a MEF-35 SLM section.
The duration of an Availability Window (in milliseconds) is
tmnxOamPmCfgTwampLtTxFrmsPerDelT * tmnxOamPmCfgTwampLtInterval *
tmnxOamPmCfgTwampLtConsecDeltaTs. An attempt to change the duration of
an Availability Window to more than 100,000 milliseconds will be
rejected.
An attempt to change tmnxOamPmCfgTwampLtConsecDeltaTs to a value less
than or equal to tmnxOamPmCfgTwampLtChliThreshold will be rejected.
Context
- MIB
- TIMETRA-OAM-PM-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.92.1.3.9.1.11- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- tmnxOamPmCfgTwampLtEntry
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 2-10