tmnxOamPmCfgSessEthSrcMdIndex

TIMETRA-OAM-PM-MIB · .1.3.6.1.4.1.6527.3.1.2.92.1.3.4.1.2

Object

column r/w Unsigned32
The value of tmnxOamPmCfgSessEthSrcMdIndex specifies the source
Ethernet Maintenance Domain (MD) index to be used by the specified
session.
              
The source domain can be specified using tmnxOamPmCfgSessEthSrcMdName
or tmnxOamPmCfgSessEthSrcMdIndex (not both).
tmnxOamPmCfgSessEthSrcMdName is the preferred object for specifying
the source domain.
              
One of tmnxOamPmCfgSessEthSrcMdName and tmnxOamPmCfgSessEthSrcMdIndex
should be assigned a non-default value. Otherwise, an attempt to start
any test belonging to the session will fail.
              
If specified, tmnxOamPmCfgSessEthSrcMdIndex should match a domain
created using TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMdMgmtRowStatus.
Otherwise, the session's tests will fail.
              
An attempt to change TIMETRA-SYSTEM-MIB::tmnxSysMgmtIfWriteMode.0 away
from 'classic(1)' is blocked if any tmnxOamPmCfgSessEthSrcMdIndex has
a non-default value.
              
Zero indicates a value has not been configured.

Context

MIB
TIMETRA-OAM-PM-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.92.1.3.4.1.2
Type
column
Access
readwrite
Status
current
Parent
tmnxOamPmCfgSessEthEntry

Syntax

Unsigned32

Values & Constraints

No enumerated values or constraints recorded.