tmnxOamPmCfgSessEthSrcMaIndex

TIMETRA-OAM-PM-MIB · .1.3.6.1.4.1.6527.3.1.2.92.1.3.4.1.3

Object

column r/w Unsigned32
The value of tmnxOamPmCfgSessEthSrcMaIndex specifies the source
Ethernet Maintenance Association (MA) index to be used by the
specified session.
              
The source association can be specified using
tmnxOamPmCfgSessEthSrcMaName or tmnxOamPmCfgSessEthSrcMaIndex (not
both).  tmnxOamPmCfgSessEthSrcMaName is the preferred object for
specifying the source association.
              
One of tmnxOamPmCfgSessEthSrcMaName and tmnxOamPmCfgSessEthSrcMaIndex
should be assigned a non-default value. Otherwise, an attempt to start
any test belonging to the session will fail.
              
If specified, tmnxOamPmCfgSessEthSrcMaIndex should match an
association created using
TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMaMgmtRowStatus. Otherwise, the
session's tests will fail.
              
An attempt to change TIMETRA-SYSTEM-MIB::tmnxSysMgmtIfWriteMode.0 away
from 'classic(1)' is blocked if any tmnxOamPmCfgSessEthSrcMaIndex has
a non-default value.
              
Zero indicates a value has not been configured.

Context

MIB
TIMETRA-OAM-PM-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.92.1.3.4.1.3
Type
column
Access
readwrite
Status
current
Parent
tmnxOamPmCfgSessEthEntry

Syntax

Unsigned32

Values & Constraints

No enumerated values or constraints recorded.