tmnxOamPmCfgLossLmmConsecDeltaTs
TIMETRA-OAM-PM-MIB ·
.1.3.6.1.4.1.6527.3.1.2.92.1.3.12.1.9
Object
column
r/w
Unsigned32
The value of tmnxOamPmCfgLossLmmConsecDeltaTs specifies the number of
consecutive MEF-35 'delta_t's (also known as 'Small Time Intervals')
which constitute a MEF-35 'Availability Window' when computing
availability statistics for the specified session's LMM test.
The availability parameters used by SROS for LMM tests (e.g.
tmnxOamPmCfgLossLmmConsecDeltaTs) are modelled after the MEF-35
availability parameters defined for Synthetic Loss Measurement (SLM)
tests. Hence, the REFERENCE text for this object is a MEF-35 SLM
section.
The duration of an Availability Window (in milliseconds) is
tmnxOamPmCfgLossLmmTxFrmsPerDelT * tmnxOamPmCfgLossLmmInterval *
tmnxOamPmCfgLossLmmConsecDeltaTs. An attempt to change the duration of
an Availability Window to more than 100,000 milliseconds will be
rejected.
An attempt to change tmnxOamPmCfgLossLmmConsecDeltaTs to a value less
than or equal to tmnxOamPmCfgLossLmmChliThreshold will be rejected.
Context
- MIB
- TIMETRA-OAM-PM-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.92.1.3.12.1.9- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- tmnxOamPmCfgLossLmmEntry
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 2-10