tmnxDot1agCfmMepSlmTWInterval
TIMETRA-IEEE8021-CFM-MIB ·
.1.3.6.1.4.1.6527.3.1.2.52.7.4.1.5
Object
column
r/w
Unsigned32
The value of tmnxDot1agCfmMepSlmTWInterval, in conjunction with
tmnxDot1agCfmMepSlmTWIntrvlUnits, specifies the interval between
Synthetic Loss Measurement (SLM) messages sent by the two-way SLM
test. For example, if tmnxDot1agCfmMepSlmTWInterval has the value 90,
and tmnxDot1agCfmMepSlmTWIntrvlUnits has the value 'centiseconds(2)',
the interval between SLM messages is 0.9 seconds.
The tmnxDot1agCfmMepSlmTWInterval and tmnxDot1agCfmMepSlmTWIntrvlUnits
pair provide support for the following intervals:
0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 0.9 seconds;
1, 2, 3, 4, 5, 6, 7, 8, 9, 10 seconds.
Context
- MIB
- TIMETRA-IEEE8021-CFM-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.52.7.4.1.5- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- tmnxDot1agCfmMepSlmTWTestEntry
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 1-90