tmnxDot3OamErrSymPrdSdThreshold
TIMETRA-DOT3-OAM-MIB ·
.1.3.6.1.4.1.6527.3.1.2.42.5.2.1.12
Object
column r/w
symbolsUnsigned32
The value of tmnxDot3OamErrSymPrdSdThreshold specifies the Signal
Degrade (SD) threshold for symbol period errors. This object's value
must be lower than the Signal Failure (SF) threshold,
dot3OamErrFramePeriodThresholdLo.
If the number of symbol errors within dot3OamErrSymPeriodWindowLo is
equal to or greater than tmnxDot3OamErrSymPrdSdThreshold and
tmnxDot3OamErrSymPrdEnabled is set to 'enabled (1)', the port is
considered degraded but still functional, and a
tmnxDot3OamSdThresholdEvent notification is generated.
A value of 0 indicates this SD threshold is ignored.
Context
- MIB
- TIMETRA-DOT3-OAM-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.42.5.2.1.12- Type
- column
- Access
- readwrite
- Status
- current
- Units
- symbols
- Parent
- tmnxDot3OamEventConfigEntry
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'TIMETRA-DOT3-OAM-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-DOT3-OAM-MIB::tmnxDot3OamErrSymPrdSdThreshold'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'TIMETRA-DOT3-OAM-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-DOT3-OAM-MIB::tmnxDot3OamErrSymPrdSdThreshold.<index>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TIMETRA-DOT3-OAM-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-DOT3-OAM-MIB::tmnxDot3OamErrSymPrdSdThreshold'
Syntax
symbolsUnsigned32
Values & Constraints
Object Constraints
range: 0-1000000
Conformance
Member of