tmnxIPsecIsaGrpTunnelReassembly
TIMETRA-CHASSIS-MIB ·
.1.3.6.1.4.1.6527.3.1.2.2.3.18.1.13
Object
column
r/w
milliseconds Integer32
The value of tmnxIPsecIsaGrpTunnelReassembly specifies the maximum
number of milliseconds to wait to receive all fragments of a
particular IPSec or GRE packet for reassembly.
The tmnxGreTunnelReassembly value set to zero indicates that
reassembly is disabled.
An 'inconsistentValue' error is returned if the value is not a
multiple of 100 milliseconds.
Context
- MIB
- TIMETRA-CHASSIS-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.2.3.18.1.13- Type
- column
- Access
- readwrite
- Status
- current
- Units
- milliseconds
- Parent
- tmnxIPsecIsaGrpEntry
Syntax
milliseconds Integer32
Values & Constraints
Object Constraints
range: 0-5000