tSyncIfTimingAdmBITSOutSource
TIMETRA-CHASSIS-MIB ·
.1.3.6.1.4.1.6527.3.1.2.2.8.2.1.1.28
Object
column
r/w
TmnxBITSOutSource
The value of tSyncIfTimingAdmBITSOutSource specifies the source of the
BITS (Building Integrated Timing Supply) output.
In an XRS-40 system, the extension chassis is synchronized with the
master chassis via the BITS ports. Two modes of operation are
permitted:
1) The BITS output ports of the master chassis CPMs are connected to
the BITS input ports of the extension chassis CPMs. In this mode,
tSyncIfTimingAdmBITSOutSource should be set to 'internalClock(2)',
to ensure that a valid clock signal is transmitted on the master
chassis's CPMs' BITS output ports.
2) The BITS input ports of all 4 CPMs are connected to external BITS
equipment. In this mode, the customer may connect the master
chassis's BITS output ports to the external BITS equipment's input
ports. This allows for recovered line references to be provided as
a frequency source into the external BITS equipment following the
inter-site synchronization mode of SDH/SONET. In this case,
tSyncIfTimingAdmBITSOutSource should be set to 'lineRef(1)'.
Context
- MIB
- TIMETRA-CHASSIS-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.2.8.2.1.1.28- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- tSyncIfTimingAdmEntry
Syntax
TmnxBITSOutSource
Values & Constraints