Configure an on-board Slave KDC.
Input string format:
<realm,master_hostname,master_ip,interface>
Input string length limits:
realm: 32 characters
hostname: 50 characters
For realm, the following characters are not allowed:
` @ # $ & ( ) = | \ ; double-quote ' < > / sp
And for hostname, only the following characters are allowed:
0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz_-
Also, '_' and '-' cannot be the first or last character of the hostname.
interface could be 1 or 2 (etherport no.)
Note:
If the on-board KDC is already configured as master or slave
then reconfiguring is not possible till the earlier configuration
is deleted.