ccdot11FHCurrentDwellTime
SYMBOL-WS5000-MIB ·
.1.3.6.1.4.1.388.6.2.14.1.5
Object
The current time in TU that the transmitter shall operate on a single channel, as set by the MAC. The valid range is from 25 to 1000 milliseconds (both inclusive). A value of 65535 returned by the switch indicates that there is no value set for this variable.
Context
- MIB
- SYMBOL-WS5000-MIB
- OID
.1.3.6.1.4.1.388.6.2.14.1.5- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- ccdot11FHPhyEntry
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SYMBOL-WS5000-MIB' -M '/opt/observium/mibs/symbol:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SYMBOL-WS5000-MIB::ccdot11FHCurrentDwellTime'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'SYMBOL-WS5000-MIB' -M '/opt/observium/mibs/symbol:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SYMBOL-WS5000-MIB::ccdot11FHCurrentDwellTime.<ccdot11FHIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'SYMBOL-WS5000-MIB' -M '/opt/observium/mibs/symbol:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'SYMBOL-WS5000-MIB::ccdot11FHCurrentDwellTime'
Syntax
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Conformance
Member of