ccMuSigStatsNoiseBest

SYMBOL-WS5000-MIB · .1.3.6.1.4.1.388.6.16.3.100.2.1.7

Object

The best noise value heard by the Radio to which this MU is associated.
Here Best value of Noise implies the the least noise value.

Context

MIB
SYMBOL-WS5000-MIB
OID
.1.3.6.1.4.1.388.6.16.3.100.2.1.7
Type
column
Access
readonly
Status
current
Units
dBm
Parent
ccMuSigStatsEntry
Groups
1

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SYMBOL-WS5000-MIB' -M '/opt/observium/mibs/symbol:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SYMBOL-WS5000-MIB::ccMuSigStatsNoiseBest'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'SYMBOL-WS5000-MIB' -M '/opt/observium/mibs/symbol:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SYMBOL-WS5000-MIB::ccMuSigStatsNoiseBest.<ccMuMac>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'SYMBOL-WS5000-MIB' -M '/opt/observium/mibs/symbol:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'SYMBOL-WS5000-MIB::ccMuSigStatsNoiseBest'

Syntax

Source
SNMPv2-SMIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647

Conformance