sub10UnitMgmtAlarmClearOper
SUB10SYSTEMS-MIB ·
.1.3.6.1.4.1.39003.3.2.6.1.1.9
Object
column
r/w
Sub10AlarmOperation
Type of operation which determines when an alarm
is to be cleared.
Definition of each type is as follows:
lt - Measured objects value is less than clear threshold
gt - Measured objects value is greater than clear threshold
le - Measured objects value is less than or equal to clear threshold
ge - Measured objects value is greater than or equal to clear threshold
eq - Measured objects value is equal to clear threshold
neq - Measured objects value is not equal to clear threshold
The alarm operation defines how to apply the configured
thresholds when clearing the alarm. This defines
whether the alarm is cleared when the measured object value
crosses the threshold from low to high or from high to low or
if the measured value hits a certain value or not.
Example:
Alarm Name Alarm Threshold Clear Operation
High Temperature 60 le
Low Temperature -30 gt
Low Temperature Alarm is cleared when the measured temperature
is lower or equal to 60 and Low Temperature cleared when the
measured temperature is greater than -30.
Context
- MIB
- SUB10SYSTEMS-MIB
- OID
.1.3.6.1.4.1.39003.3.2.6.1.1.9- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- sub10UnitMgmtAlarmEntry
Syntax
Sub10AlarmOperation
Values & Constraints
No enumerated values or constraints recorded.