snMspsSyslogFwdTransType
SN-MSPS-SCX-MIB ·
.1.3.6.1.4.1.4329.20.1.1.1.1.21.1.20.1.5
Object
column r/w
Enumeration
Specifies the Transport type using which it can send syslog message. By default the tranport type is udp
Context
- MIB
- SN-MSPS-SCX-MIB
- OID
.1.3.6.1.4.1.4329.20.1.1.1.1.21.1.20.1.5- Type
- column
- Access
- readwrite
- Status
- current
- Default
udp- Parent
- snMspsSyslogFwdEntry
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SN-MSPS-SCX-MIB' -M '/opt/observium/mibs/siemens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SN-MSPS-SCX-MIB::snMspsSyslogFwdTransType'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'SN-MSPS-SCX-MIB' -M '/opt/observium/mibs/siemens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SN-MSPS-SCX-MIB::snMspsSyslogFwdTransType.<snMspsSyslogFwdPriority>.<snMspsSyslogFwdAddressType>.<snMspsSyslogFwdServerIP>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'SN-MSPS-SCX-MIB' -M '/opt/observium/mibs/siemens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'SN-MSPS-SCX-MIB::snMspsSyslogFwdTransType'
Syntax
Enumeration
Values & Constraints
Enumerated Values
0 | udp |
1 | tcp |
2 | beep |