snMspsPimSPTSourceThreshold
SN-MSPS-SCX-MIB ·
.1.3.6.1.4.1.4329.20.1.1.1.1.76.1.1.3
Object
scalar r/w
Integer32
The threshold of data rate for any source when exceeded, switching to Shortest Path Tree is initiated. It is based on number of bits per sec. To switch to SPT, this threshold MUST be configured
Context
- MIB
- SN-MSPS-SCX-MIB
- OID
.1.3.6.1.4.1.4329.20.1.1.1.1.76.1.1.3- Type
- scalar
- Access
- readwrite
- Status
- current
- Default
0- Parent
- snMspsPimScalars
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'SN-MSPS-SCX-MIB' -M '/opt/observium/mibs/siemens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SN-MSPS-SCX-MIB::snMspsPimSPTSourceThreshold.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'SN-MSPS-SCX-MIB' -M '/opt/observium/mibs/siemens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'SN-MSPS-SCX-MIB::snMspsPimSPTSourceThreshold'
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-2147483647