snMspsNtpCommonTraceFlag
SN-MSPS-SCX-MIB ·
.1.3.6.1.4.1.4329.20.1.1.1.1.33.1.4
Object
scalar r/w
Unsigned32
This object used to configure the trace level of the NTP module. Find the values and corresponding trace information 1.Disable traces 0x00000000 2.Error traces 0x00000001 3.Failure traces 0x00000002 4.Info traces 0x00000004 5.HighInfo traces 0x00000008 6.Debug traces 0x00000010 7.All traces 0x000000ff and it can be combination of the all above.
Context
- MIB
- SN-MSPS-SCX-MIB
- OID
.1.3.6.1.4.1.4329.20.1.1.1.1.33.1.4- Type
- scalar
- Access
- readwrite
- Status
- current
- Default
0- Parent
- snMspsNtpCommon
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'SN-MSPS-SCX-MIB' -M '/opt/observium/mibs/siemens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SN-MSPS-SCX-MIB::snMspsNtpCommonTraceFlag.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'SN-MSPS-SCX-MIB' -M '/opt/observium/mibs/siemens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'SN-MSPS-SCX-MIB::snMspsNtpCommonTraceFlag'
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 0-255