snMspsMstCistBridgeMaxAge

SN-MSPS-SCX-MIB · .1.3.6.1.4.1.4329.20.1.1.1.1.6.15

Object

scalar r/w centi-secondsBRIDGE-MIBTimeout
The value that all bridges use for MaxAge when
this bridge is acting as the root. The granularity 
of this timer is specified to be 1 second.
An agent may return a badValue error if a set is
attempted to a value which is not a whole number
of seconds.

Context

MIB
SN-MSPS-SCX-MIB
OID
.1.3.6.1.4.1.4329.20.1.1.1.1.6.15
Type
scalar
Access
readwrite
Status
current
Units
centi-seconds
Default
2000
Parent
snMspsMstp

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'SN-MSPS-SCX-MIB' -M '/opt/observium/mibs/siemens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SN-MSPS-SCX-MIB::snMspsMstCistBridgeMaxAge.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'SN-MSPS-SCX-MIB' -M '/opt/observium/mibs/siemens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'SN-MSPS-SCX-MIB::snMspsMstCistBridgeMaxAge'

Syntax

centi-secondsBRIDGE-MIBTimeout
Source
BRIDGE-MIBTimeout
Base type
Integer32

Values & Constraints

Object Constraints
range: 600-4000