snMspsMstCistBridgeMaxAge
SN-MSPS-SCX-MIB ·
.1.3.6.1.4.1.4329.20.1.1.1.1.6.15
Object
The value that all bridges use for MaxAge when this bridge is acting as the root. The granularity of this timer is specified to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds.
Context
- MIB
- SN-MSPS-SCX-MIB
- OID
.1.3.6.1.4.1.4329.20.1.1.1.1.6.15- Type
- scalar
- Access
- readwrite
- Status
- current
- Units
- centi-seconds
- Default
2000- Parent
- snMspsMstp
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'SN-MSPS-SCX-MIB' -M '/opt/observium/mibs/siemens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SN-MSPS-SCX-MIB::snMspsMstCistBridgeMaxAge.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'SN-MSPS-SCX-MIB' -M '/opt/observium/mibs/siemens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'SN-MSPS-SCX-MIB::snMspsMstCistBridgeMaxAge'
Syntax
centi-secondsBRIDGE-MIBTimeout
- Source
- BRIDGE-MIBTimeout
- Base type
Integer32
Values & Constraints
Object Constraints
range: 600-4000