snMspsConfigSourceIpVlanId
SN-MSPS-SCX-MIB ·
.1.3.6.1.4.1.4329.20.1.1.1.1.1.101
Object
scalar r/w
Integer32
Configures the LoopBack IP interface VLAN ID (1 to 4094).
Non-Zero IPv4/IPv6 Address of this LoopBack interface will be
used as Source Address for management communication.
Using of Loopback IP as source IP is applicable for Syslog,
SMTP, NTP, SNTP, Radius and SNMP Packets generated from this
device.
If snMspsConfigSourceIpVlanId is 0, then this feature
is disabled.
If snMspsConfigSourceIpVlanId in non-zero,
and if the corresponding Loopback interface has IPv4 Address as
0.0.0.0, then this feature is disabled for all IPv4 management
communication.
If the loopback interface does not have an
active IPv6 Global Address, then this feature is disabled for
all IPv6 management communication.
Context
- MIB
- SN-MSPS-SCX-MIB
- OID
.1.3.6.1.4.1.4329.20.1.1.1.1.1.101- Type
- scalar
- Access
- readwrite
- Status
- current
- Default
0- Parent
- snMspsConfig
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'SN-MSPS-SCX-MIB' -M '/opt/observium/mibs/siemens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SN-MSPS-SCX-MIB::snMspsConfigSourceIpVlanId.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'SN-MSPS-SCX-MIB' -M '/opt/observium/mibs/siemens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'SN-MSPS-SCX-MIB::snMspsConfigSourceIpVlanId'
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-4094