sleAlarmRisingThreshold

SLE-RMON-MIB · .1.3.6.1.4.1.6296.101.9.2.1.1.7

Object

column Integer32
A threshold for the sampled statistic.  When the
current sampled value is greater than or equal to
this threshold, and the value at the last sampling
interval was less than this threshold, a single
event will be generated.  A single event will also
be generated if the first sample after this entry
becomes valid is greater than or equal to this
threshold and the associated alarmStartupAlarm is
equal to risingAlarm(1) or risingOrFallingAlarm(3).
              
After a rising event is generated, another such event
will not be generated until the sampled value
falls below this threshold and reaches the
alarmFallingThreshold.
              
This object may not be modified if the associated
alarmStatus object is equal to valid(1).

Context

MIB
SLE-RMON-MIB
OID
.1.3.6.1.4.1.6296.101.9.2.1.1.7
Type
column
Access
readonly
Status
current
Parent
sleAlarmEntry

Syntax

Integer32

Values & Constraints

No enumerated values or constraints recorded.