equipManagerWakeUpTimeout
SIAE-EQUIP-MIB ·
.1.3.6.1.4.1.3373.1103.1.24
Object
scalar r/w
Integer32
This object defines the time (in minutes) after which the periodic connection wake-up trap is stopped. The maximium value is equivalent to 24 hours. When the timeout elapses the equipManagerWakeUpAlarmSeverityCode is set to disable. A zero means no timeout.
Context
- MIB
- SIAE-EQUIP-MIB
- OID
.1.3.6.1.4.1.3373.1103.1.24- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- equipment
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'SIAE-EQUIP-MIB' -M '/opt/observium/mibs/siaemic:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SIAE-EQUIP-MIB::equipManagerWakeUpTimeout.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'SIAE-EQUIP-MIB' -M '/opt/observium/mibs/siaemic:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'SIAE-EQUIP-MIB::equipManagerWakeUpTimeout'
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-1440