equipConfigChange

SIAE-EQUIP-MIB · .1.3.6.1.4.1.3373.1103.1.14

Object

scalar r/w OctetString
Set by the NE when the equipment configuration is changed by the local
or Remote LOM.
The octet string is a bit stream of flags; a set bit is a change on a
specific item. We had:
Byte 0.7: change in configuration for equipment group
Byte 0.6: change in configuration for userInput group
Byte 0.5: change in configuration for userOutput group
Byte 0.4: change in configuration for alarmLog group
......
Byte 3.7: change in a severity for equipment group
Byte 3.6: change in a severity for userInput group
Byte 3.5: change in a severity for userOutput group
Byte 3.4: change in a severity for alarmLog group
CEM can reset the change condition writing one to desired bit flag
......

Context

MIB
SIAE-EQUIP-MIB
OID
.1.3.6.1.4.1.3373.1103.1.14
Type
scalar
Access
readwrite
Status
current
Parent
equipment

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'SIAE-EQUIP-MIB' -M '/opt/observium/mibs/siaemic:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SIAE-EQUIP-MIB::equipConfigChange.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'SIAE-EQUIP-MIB' -M '/opt/observium/mibs/siaemic:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'SIAE-EQUIP-MIB::equipConfigChange'

Syntax

OctetString

Values & Constraints

Object Constraints
range: 6-6