hmtsDevReturnLvl

SCTE-HMS-HMTS-MIB · .1.3.6.1.4.1.5591.1.11.3.2.1.3.6.1.7

Object

column 0.1 dBmVSNMPv2-SMIInteger32
This is the return level as recorded on the last response from
this device.  This value only applies to transponders that are
accessed via the serial RF link, noSuchName shall be returned when
the device is accessed via other serial interfaces.  This value is
reported in tenths of dBmV.  The value -999 shall be returned
if a level has not yet been measured on this receiver.
              
This object has a threshold property in the propertyTable as
defined in SCTE 38-1 (formerly HMS026).  The threshold limits and
enables can be globally set by the hmtsRevReturnLvl object's
thresholds. Individual control of this object's threshold properties
can be set through the threshold properties of this object.
Alarms for this parameter shall report the hmtsRevPortId as the value
of heCommonLogText within the heCommonAlarmEvent.

Context

MIB
SCTE-HMS-HMTS-MIB
OID
.1.3.6.1.4.1.5591.1.11.3.2.1.3.6.1.7
Type
column
Access
readonly
Status
current
Units
0.1 dBmV
Parent
hmtsDevEntry
Groups
1

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCTE-HMS-HMTS-MIB' -M '/opt/observium/mibs/scte:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCTE-HMS-HMTS-MIB::hmtsDevReturnLvl'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'SCTE-HMS-HMTS-MIB' -M '/opt/observium/mibs/scte:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCTE-HMS-HMTS-MIB::hmtsDevReturnLvl.<hmtsDevPhysAddr>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'SCTE-HMS-HMTS-MIB' -M '/opt/observium/mibs/scte:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'SCTE-HMS-HMTS-MIB::hmtsDevReturnLvl'

Syntax

Source
SNMPv2-SMIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647

Conformance