saCmAutoResetNoActivity

SA-CM-MIB · .1.3.6.1.4.1.1429.77.1.4.10

Object

scalar r/w minutesInteger32
Setting this object to any value N > 0 will cause the CM to reboot autonomously
3/4th of N minutes after the modem has detected that there is no connectivity to the CM gateway after three unsuccessful pings. 
NOTE: The default value of 0 means the feature is disabled.

Context

MIB
SA-CM-MIB
OID
.1.3.6.1.4.1.1429.77.1.4.10
Type
scalar
Access
readwrite
Status
current
Units
minutes
Parent
cmInterfaceInfo

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'SA-CM-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SA-CM-MIB::saCmAutoResetNoActivity.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'SA-CM-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'SA-CM-MIB::saCmAutoResetNoActivity'

Syntax

minutesInteger32

Values & Constraints

Object Constraints
range: 0-43200