rcPoeMinimumVoltage
RUGGEDCOM-POE-MIB ·
.1.3.6.1.4.1.15004.4.7.1.2
Object
scalar r/w
VInteger32
The minimum required voltage to be provided by PoE ports.
The minimum required voltage for PoE ports.
When PoE voltage droppes below this threshold, low priority PoE ports
will be shutdown.
Context
- MIB
- RUGGEDCOM-POE-MIB
- OID
.1.3.6.1.4.1.15004.4.7.1.2- Type
- scalar
- Access
- readwrite
- Status
- current
- Units
- V
- Parent
- rcPoeBase
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'RUGGEDCOM-POE-MIB' -M '/opt/observium/mibs/siemens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RUGGEDCOM-POE-MIB::rcPoeMinimumVoltage.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'RUGGEDCOM-POE-MIB' -M '/opt/observium/mibs/siemens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'RUGGEDCOM-POE-MIB::rcPoeMinimumVoltage'
Syntax
VInteger32
Values & Constraints
Object Constraints
range: 39-57
Conformance
Member of