rc2kBootConfigLinerateDirectedBroadcast

RC-2K-MIB · .1.3.6.1.4.1.2272.1.100.5.1.56

Object

column r/w SNMPv2-TCTruthValue
Flag to Enable or Disable Linerate Directed Broadcast.
With this flag set, IP directed broadcast will operate
at linerate. Without this flag, all IP directed broadcast
is handled in legacy mode by the CP and is limited to
a few hundred pps. When booted with the flag set, 
faceplate port 1/48 is removed from service and
recommissioned as a loopback port to which all directed
broadcast traffic is sent. The traffic can then reenter
the pipeline and flooded over the VLAN at linrate.

Context

MIB
RC-2K-MIB
OID
.1.3.6.1.4.1.2272.1.100.5.1.56
Type
column
Access
readwrite
Status
current
Parent
rc2kBootConfigEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RC-2K-MIB' -M '/opt/observium/mibs/nortel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RC-2K-MIB::rc2kBootConfigLinerateDirectedBroadcast'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'RC-2K-MIB' -M '/opt/observium/mibs/nortel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RC-2K-MIB::rc2kBootConfigLinerateDirectedBroadcast.<rc2kBootConfigSlot>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'RC-2K-MIB' -M '/opt/observium/mibs/nortel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'RC-2K-MIB::rc2kBootConfigLinerateDirectedBroadcast'

Syntax

Source
SNMPv2-TCTruthValue
Base type
Enumeration
Type Description
Represents a boolean value.

Values & Constraints

Type Values
1true
2false