rcTengIfName

RAPID-CITY · .1.3.6.1.4.1.2272.1.50.1.4.1.2

Object

The textual name of the interface.  The value of this
object should be the name of the interface as assigned
by the local device and should be suitable for use in
commands entered at the device's `console'.  This
might be a text name, such as `le0' or a simple port
number, such as `1', depending on the interface naming
syntax of the device.  If several entries in the
rcTengIfTable together represent a single interface as 
named	by the device, then each will have the same 
value of rcTengIfName.  If there is no local name, or 
this object is otherwise not applicable, then this 
object contains a 0-length string.

Context

MIB
RAPID-CITY
OID
.1.3.6.1.4.1.2272.1.50.1.4.1.2
Type
column
Access
readonly
Status
current
Parent
rcTengIfXEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RAPID-CITY' -M '/opt/observium/mibs/nortel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RAPID-CITY::rcTengIfName'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'RAPID-CITY' -M '/opt/observium/mibs/nortel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RAPID-CITY::rcTengIfName.<index>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'RAPID-CITY' -M '/opt/observium/mibs/nortel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'RAPID-CITY::rcTengIfName'

Syntax

Source
SNMPv2-TCDisplayString
Base type
OctetString
Display format
255a
Type Description
Represents textual information taken from the NVT ASCII
          
character set, as defined in pages 4, 10-11 of RFC 854.
          
To summarize RFC 854, the NVT ASCII repertoire specifies:
          
  - the use of character codes 0-127 (decimal)
          
  - the graphics characters (32-126) are interpreted as
    US ASCII
          
  - NUL, LF, CR, BEL, BS, HT, VT and FF have the special
    meanings specified in RFC 854
          
  - the other 25 codes have no standard interpretation
          
  - the sequence 'CR LF' means newline
          
  - the sequence 'CR NUL' means carriage-return
          
  - an 'LF' not preceded by a 'CR' means moving to the
    same column on the next line.
          
  - the sequence 'CR x' for any x other than LF or NUL is
    illegal.  (Note that this also means that a string may
    end with either 'CR LF' or 'CR NUL', but not with CR.)
          
Any object defined using this syntax may not exceed 255
characters in length.

Values & Constraints

Type Constraints
range: 0..255