rcPlugOptModTemperature
OBS ✓
RAPID-CITY ·
.1.3.6.1.4.1.2272.1.71.1.1.17
Object
column SNMPv2-SMIInteger32
This value represents the internally measured module temperature. It is expressed in units of 1/256 of a degree Celsius and can range from -40C to +125C with 0.0001 accuracy.The most significant byte is the signed integer part of the number and the least significant byte is the fraction.
Observium directly uses this object
This object is referenced by an Observium discovery or polling workflow.
Used in:
Sensors
Explore Observium network monitoring
Context
- MIB
- RAPID-CITY
- OID
.1.3.6.1.4.1.2272.1.71.1.1.17- Type
- column
- Access
- readonly
- Status
- current
- Parent
- rcPlugOptModEntry
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RAPID-CITY' -M '/opt/observium/mibs/nortel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RAPID-CITY::rcPlugOptModTemperature'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'RAPID-CITY' -M '/opt/observium/mibs/nortel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RAPID-CITY::rcPlugOptModTemperature.<index>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'RAPID-CITY' -M '/opt/observium/mibs/nortel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'RAPID-CITY::rcPlugOptModTemperature'
Syntax
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647