rcPlugOptModTxPowerLowAlarmThreshold

RAPID-CITY-VSP · .1.3.6.1.4.1.2272.1.71.1.1.34

Object

This value represents the vendor specified low
transmit power threshold. If the measured
transmitter power falls below this value, a
transmitter power low is asserted. It is a
positive number expressed in units of micro watts
and can range from 0 to 65.535 mW (-40 to 18.16 dBm).

Context

MIB
RAPID-CITY-VSP
OID
.1.3.6.1.4.1.2272.1.71.1.1.34
Type
column
Access
readonly
Status
current
Parent
rcPlugOptModEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RAPID-CITY-VSP' -M '/opt/observium/mibs/nortel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RAPID-CITY-VSP::rcPlugOptModTxPowerLowAlarmThreshold'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'RAPID-CITY-VSP' -M '/opt/observium/mibs/nortel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RAPID-CITY-VSP::rcPlugOptModTxPowerLowAlarmThreshold.<rcPlugOptModPortIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'RAPID-CITY-VSP' -M '/opt/observium/mibs/nortel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'RAPID-CITY-VSP::rcPlugOptModTxPowerLowAlarmThreshold'

Syntax

Source
SNMPv2-SMIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647