This parameter defines the signal pattern for inband loopback
activation and deactivation:
csu
Applicable only for SF (D4) and ESF line types
Defined in AT&T TR54016 and ANSI T1.403.
Loop-up pattern - 00001 detected for at least 5 seconds
Loop-down pattern - 001 detected for at least 5 seconds
fdlLine
Applicable only for ESF line type.
Defined in ANSI T1.403.
Loop-up pattern - 00001110 11111111
Loop-down pattern - 00111000 11111111 or 00100100 11111111 (universal deactivate)
fdlNetwork
Applicable only for ESF line type.
Defined in ANSI T1.403.
Loop-up pattern - 00010010 11111111
Loop-down pattern - 00100100 11111111
niuFac1
Applicable for framed and unframed line types.
Define in Telcordia (Bellcore) TR-TSY-0312.
Loop-up pattern - 0011
Loop-down pattern - 0111
niuFac2
Applicable for framed and unframed line types.
Define in Telcordia (Bellcore) TR-TSY-0312.
Loop-up pattern - 00011
Loop-down pattern - 00111
program
User configurable loop-up and loop-down patterns.
The patterns and their length are set in:
dsx1InbandLoopUpCode
dsx1InbandLoopUpLength
dsx1InbandLoopDownCode
dsx1InbandLoopDownLength
The specified pattern is applicable only when the value of
dsx1CsuLoop is local(2) or remote(4).
This parameter is applicable only for T1.
Context
- MIB
- RAD-ds1Interface-MIB
- OID
.1.3.6.1.4.1.164.3.1.6.4.2.1.24- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- dsx1XConfigEntry
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | notApplicable |
2 | csu |
3 | fdlLine |
4 | fdlNetwork |
5 | niuFac1 |
6 | niuFac2 |
99 | program |