prtSonetCurrentXStatus
RAD-Sonet-MIB ·
.1.3.6.1.4.1.164.3.1.6.2.1.2.1.13
Object
column
Integer32
This variable indicates the Status of the interface.
It contains failure state information.
The variable is a bit map represented as a sum, therefore,
it can represent multiple failures simultaneously.
The sonetSectionLineNoDefect must be set if and only if no
other flag is set.
The various bit positions are:
1 sonetSectionLineNoDefect
2 sonetSectionLOS Loss Of Signal
4 sonetSectionLOF Loss Of Frame
8 sonetSectionLOC Loss Of Clock
16 sonetLineAIS Alarm Indication Signal
32 sonetLineRDI Remote Defect Indication
64 sonetLineRFI Remote Failure Indication
(RDI lasts for 2.5 (+-0.5) seconds)
128 sonetLineEBER Excessive Bit Error Rate (i.e.EED)
256 sonetLineSD Signal Degradation
512 sonetOOF Out Of Frame
1024 sonetSectionTIM Trace Identifier Mismatch
Context
- MIB
- RAD-Sonet-MIB
- OID
.1.3.6.1.4.1.164.3.1.6.2.1.2.1.13- Type
- column
- Access
- readonly
- Status
- current
- Parent
- prtSectionLineCurrentEntry
Syntax
Integer32
Values & Constraints
Enumerated Values
1 | notApplicable |
2 | disable |