dot1agXCfmMepCcStatus
RAD-OamCfm-MIB ·
.1.3.6.1.4.1.164.3.1.6.1.3.9.1.24
Object
column
Bits
This obejct indicates the Continuity Check status. If no bit is set then it means that the ststus is ok. If notApplicable (0) is set then the other bits should not be set. If otherFail (1) is set then the other bits should not be set.
Context
- MIB
- RAD-OamCfm-MIB
- OID
.1.3.6.1.4.1.164.3.1.6.1.3.9.1.24- Type
- column
- Access
- readonly
- Status
- current
- Parent
- dot1agXCfmMepEntry
Syntax
Bits
Values & Constraints
Enumerated Values
0 | notApplicable |
1 | otherFail |
2 | mismerge |
3 | unexpectedMep |
4 | unexpectedMepLevel |
5 | unexpectedPeriod |