prtExPhPlModemTimeBtwnCalls

RAD-Mpmx-MIB · .1.3.6.1.4.1.164.3.2.3.2.3.3.1.7

Object

column r/w SNMPv2-SMIInteger32
Minimum Time in Seconds which is required after a call was
disconnected. In this time no other call will be initiated
from this Modem port even if there were frames transmitted
to this port. This time is required for some Modems which
have initializations that take a few seconds.
              
Legal Values are:
	   0 sec. - 30 sec., 1-5 min.
65535 sec. means that this parameter is not applicable. 
              
Default: 0 sec

Context

MIB
RAD-Mpmx-MIB
OID
.1.3.6.1.4.1.164.3.2.3.2.3.3.1.7
Type
column
Access
readwrite
Status
current
Parent
prtExPhPlModemEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RAD-Mpmx-MIB' -M '/opt/observium/mibs/rad:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RAD-Mpmx-MIB::prtExPhPlModemTimeBtwnCalls'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'RAD-Mpmx-MIB' -M '/opt/observium/mibs/rad:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RAD-Mpmx-MIB::prtExPhPlModemTimeBtwnCalls.<prtExPhPlModemCnfgIdx>.<prtExPhPlModemSltIdx>.<prtExPhPlModemPrtIdx>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'RAD-Mpmx-MIB' -M '/opt/observium/mibs/rad:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'RAD-Mpmx-MIB::prtExPhPlModemTimeBtwnCalls'

Syntax

Source
SNMPv2-SMIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647