rtrIcmpRdMinAdvertInterval
RAD-MIB ·
.1.3.6.1.4.1.164.11.2.2.2.1.4
Object
column
r/w
Integer32
The minimum time allowed between sending unsolicited multicast Router Advertisements from the interface, in seconds. Must be no less than 3 seconds and no greater than rtrIcmpRdMaxAdvertInterval. Default: 0.75 * rtrIcmpRdMaxAdvertInterval.
Context
- MIB
- RAD-MIB
- OID
.1.3.6.1.4.1.164.11.2.2.2.1.4- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- rtrIcmpRdEntry
Syntax
Integer32
Values & Constraints