ringACFCErrCnt
RAD-MIB ·
.1.3.6.1.4.1.164.1.1.2.9
Object
scalar SNMPv2-SMICounter32
This counter is incremented when any of the stations on the ring receives an AMP or SMP frame in which A is equal to C is equal to 0, and then receives another SMP frame with A is equal to C is equal to 0 without first receiving an AMP frame. It denotes a station that cannot set the AC bits properly.
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'RAD-MIB' -M '/opt/observium/mibs/rad:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RAD-MIB::ringACFCErrCnt.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'RAD-MIB' -M '/opt/observium/mibs/rad:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'RAD-MIB::ringACFCErrCnt'
Syntax
- Source
- SNMPv2-SMICounter32
- Base type
Unsigned32
Values & Constraints
Object Constraints
range: 0-255
Type Constraints
range: 0..4294967295