prtMl4OosExitThreshold
RAD-MIB ·
.1.3.6.1.4.1.164.3.2.3.2.19.1.1.16
Object
column
r/w
Integer32
This object defines the number of consecutive Error-Free-Seconds before going from OOS state to Normal state. This value will be the Exit Threshold from the OOS (Out-of-Service) state. Units=seconds This object is applicable only when prtMl4OosErrorSource=framing(3) or bpv(4). 0=notApplicable.
Context
- MIB
- RAD-MIB
- OID
.1.3.6.1.4.1.164.3.2.3.2.19.1.1.16- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- prtMl4CnfgEntry
Syntax
Integer32
Values & Constraints