prtInPh1MlErrorsThreshold
RAD-MIB ·
.1.3.6.1.4.1.164.3.2.3.2.2.3.1.17
Object
column
r/w
Integer32
This object is the Max Errors. It determines the number of Status Enquiry Errors that occured within the FR sliding window, before this port is considered DOWN (threshold). This parameter is applicable only for FR and FR+ protocols AND only when prtInPh1MlFrMngProt is NOT (notApplicable or none). 0=notApplicable.
Context
- MIB
- RAD-MIB
- OID
.1.3.6.1.4.1.164.3.2.3.2.2.3.1.17- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- prtInPh1MlCnfgEntry
Syntax
Integer32
Values & Constraints
Object Constraints
range: 1-255