prtExVc2TxBitCode
RAD-MIB ·
.1.3.6.1.4.1.164.3.2.3.2.5.1.20
Object
column
r/w
OctetString
- - - For MP & FCD - - -
This object represents 4 parameters, by 2 Octets :
Tx D Bit Code-MSB nibble,
Tx C Bit Code- nibble,
Tx B Bit Code- nibble,
Tx A Bit Code-LSB nibble.
Each nibble:
0 hex = 0000 = Not Applicable
1 hex = 0001 = M lead
2 hex = 0010 = M lead inverse
3 hex = 0011 = Reverse Polarity
4 hex = 0100 = Metering Pulse
5 hex = 0101 = Forced 1
6 hex = 0110 = Forced 0
7-F hex - not used (invalid values)
This object will be RO if prtExVc2SigProfile is NOT manual.
- - - For WR II - - -
This object represents the following 4 parameters by 2 Octets:
1. On/Off hook signaling transmission mode from the FXS towards the T1/E1 (MSB nibble 1).
2. Default signaling bits that are not in use (nibble 2).
3. Ring Detection signaling transmission mode from the FXO towards the T1/E1(nibble 3).
4. M (Mouth) Signaling transmission mode from the E&M towards the T1/E1(LSB nibble 4).
Each nibble:
---------------------------------------------------------------------------------------
Value On/Off Hook Default sig. Ring Detect. M (Mouth)
---------------------------------------------------------------------------------------
0 hex = 0000 Not Applicable Not Applicable. Not Applicable Not Applicable
1 hex = 0001 Tx A bit Values 1-3 are Tx A bit Tx A bit
2 hex = 0010 Tx A bit inverse for On/Off Hook Tx A bit inv. Tx A bit inv.
3 hex = 0011 Tx B bit A,B,A Inv,B Inv. Tx B bit Tx B bit
4 hex = 0100 Tx B bit inverse Values 4-7 are Tx B bit inv. Tx B bit inv.
5 hex = 0101 not Used-invalid for On/Off Hook not Used-invalid not Used-invalid
6 hex = 0110 not Used-invalid A, A Inverse. not Used-invalid not Used-invalid
7 hex = 0111 not Used-invalid not Used-invalid not Used-invalid
8 hex = 1000 not Used-invalid Values 8-11 are not Used-invalid not Used-invalid
9 hex = 1001 not Used-invalid for On/Off Hook not Used-invalid not Used-invalid
A hex = 1010 not used-invalid B, B Inverse. not Used-invalid not Used-invalid
B hex = 1011 not used-invalid The Bits order: not Used-invalid not Used-invalid
C-F hex not used-invalid ABCD not Used-invalid not Used-invalid
Default value: 11 11
Context
- MIB
- RAD-MIB
- OID
.1.3.6.1.4.1.164.3.2.3.2.5.1.20- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- prtVc2CnfgEntry
Syntax
OctetString
Values & Constraints
Enumerated Values
2 | restoreT1secFast |
3 | restoreT10sec62411 |
4 | ccittE1 |