prtExPhPlModemCallDelay
RAD-MIB ·
.1.3.6.1.4.1.164.3.2.3.2.3.3.1.8
Object
column
r/w
Integer32
Time in Seconds that the device will wait before dialing to the remote
device.
This feature is mostly used when there is a backup modem to the
main link and the main link is down. In this case it is important to prevent
the 2 devices from dialing through the backup modems to each other at the same time.
It is advised to configure one side with a small call delay and the other side
with a large call delay.
Legal Values are:
0 - 30, 60, 120, 180, 240, 300, 600, 900, 1200, 1500, 1800 .
65535 sec. means that this parameter is not applicable.
Default: 0 sec
Context
- MIB
- RAD-MIB
- OID
.1.3.6.1.4.1.164.3.2.3.2.3.3.1.8- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- prtExPhPlModemEntry
Syntax
Integer32
Values & Constraints
Enumerated Values
1 | notApplicable |
2 | loopStart |
3 | groundStart |
4 | winkStart |