prtExPVc4WinkMaxDuration
RAD-MIB ·
.1.3.6.1.4.1.164.3.2.3.2.9.1.1.27
Object
column
r/w
Integer32
This parameter is used only for Wink Protocol. Max Duration of the Wink Signal (off hook duration from the called party). Legal values: 40..400 msec in intervals of 10 msec.
Context
- MIB
- RAD-MIB
- OID
.1.3.6.1.4.1.164.3.2.3.2.9.1.1.27- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- prtExPVc4CnfgEntry
Syntax
Integer32
Values & Constraints
Enumerated Values
2 | no |
3 | yes |