atmCbrCnfgRxTimeSlots
RAD-MIB ·
.1.3.6.1.4.1.164.12.4.3.3.1.1.9
Object
column
r/w
TimeSlots
This value indicates the time-slots used by this connection for receiving. It uses 32 bits for E1 and low 24 bits for T1. each bit represents a time slot for receiving : time-slot 0 = bit 0 (LSB - most right bit in last byte), ... ... time-slot 31 = bit 31 (MSB - most left bit in first byte ). value '0' indicate unused time-slot and value '1' indicates used time-slot. On set-request the user indicates the time-slot he needs for requested ATM-Vcc by putting '1' to the right bits. note : time-slots '0' and '16' are used for signalling in E1 interface. Currently not in use. Must be '0'.
Context
- MIB
- RAD-MIB
- OID
.1.3.6.1.4.1.164.12.4.3.3.1.1.9- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- atmCbrCnfgEntry
Syntax
TimeSlots
Values & Constraints
No enumerated values or constraints recorded.