alarmForwardingGroupConditions

RAD-MIB · .1.3.6.1.4.1.164.6.2.50.1.5

Object

column r/w SNMPv2-SMIInteger32
This parameter is applicable when there is a group of interfaces 
in which a fault may occur, and one interface to which alarm is propagated (forwarded).
0 = All - Forwarding will take place only when all interfaces of the 
same group are faulty.
1 = Single - Forwarding will take place when at least one (single)
interface of the same group (any of them) is faulty.
n - forwarding will take place only when n (n < all) 
interfaces of the same group fail.

Context

MIB
RAD-MIB
OID
.1.3.6.1.4.1.164.6.2.50.1.5
Type
column
Access
readwrite
Status
current
Parent
alarmForwardingEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RAD-MIB' -M '/opt/observium/mibs/rad:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RAD-MIB::alarmForwardingGroupConditions'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'RAD-MIB' -M '/opt/observium/mibs/rad:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RAD-MIB::alarmForwardingGroupConditions.<index>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'RAD-MIB' -M '/opt/observium/mibs/rad:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'RAD-MIB::alarmForwardingGroupConditions'

Syntax

Source
SNMPv2-SMIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647