prtParamClkSsmRxSource
RAD-GEN-MIB ·
.1.3.6.1.4.1.164.6.2.15.5.1.1.24
Object
column
r/w
Enumeration
This object indicates the Sa-bit of the E1 frame, in which SSM messages are carried.
Context
- MIB
- RAD-GEN-MIB
- OID
.1.3.6.1.4.1.164.6.2.15.5.1.1.24- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- prtParamEntry
- Table
- prtParamTable
- Siblings
- 34
Syntax
Enumeration
Values & Constraints
Enumerated Values
2 | sa4 |
3 | sa5 |
4 | sa6 |
5 | sa7 |
6 | sa8 |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| prtParamIdx This object is an index of the specific port or interface.
For a port, the index will be as agreed between agent and
application.
For an interface, ifIndex may be used.
… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.6.2.15.5.1.1.1 |
| prtParamLineLength Line Length of the line connected to this port. | column | Enumeration | .1.3.6.1.4.1.164.6.2.15.5.1.1.10 |
| prtParamUsage Defines whether this port works as User port or as Network port. | column | Enumeration | .1.3.6.1.4.1.164.6.2.15.5.1.1.11 |
| prtParamMappingMode This object defines path protection on SONET/SDH link
Auto - SONET/SDH mapping for port is copied
automatically to same TU on the redundant
SONET/SDH local (reside on same slot) … | column | Enumeration | .1.3.6.1.4.1.164.6.2.15.5.1.1.12 |
| prtParamAlarmIndication This object indicates status-aggregation of non-masked alarms
associated with all interface layers, related to this physical port.
When at least one non-masked alarm exists on an… | column | Enumeration | .1.3.6.1.4.1.164.6.2.15.5.1.1.13 |
| prtParamClkQualityLevel This parameter indicates quality level of clock signal.
Quality is encoded according to SSM
(Synchronization Status Messages) encoding.
Bits 8 -5 of byte are encoded as foll… | column | OctetString | .1.3.6.1.4.1.164.6.2.15.5.1.1.14 |
| prtParamClkWaveShape Wave shape of station clock source signal.
This parameter is applicable only when prtParamInterfaceType value
is one of the following: f1544kHz(15), f2048kHz(16). | column | Enumeration | .1.3.6.1.4.1.164.6.2.15.5.1.1.15 |
| prtParamStatus Station clock source Status. | column | Enumeration | .1.3.6.1.4.1.164.6.2.15.5.1.1.16 |
| prtParamSignalLevel This object indicates signal level (in thenth of dB units)
on selected port. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.6.2.15.5.1.1.17 |
| prtParamClkUserQualityLevel This parameter allows user to mark quality level of clock.
Quality is encoded according to SSM
(Synchronization Status Messages) encoding.
Bits 8 -5 of byte are encoded as follo… | column | OctetString | .1.3.6.1.4.1.164.6.2.15.5.1.1.18 |
| prtParamDataRate Rate of serial data port (V.11, V.24, V.35)
in kbps units. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.164.6.2.15.5.1.1.19 |
| prtControlCnfg This object may be used for port RW general parameter/s.
For detailed meaning, see product's spec.
Supported by: PRBi-E3/T3.
For ACE2002:
This parameter will includ… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.6.2.15.5.1.1.2 |
| prtParamLoopDetect Enable/disable Loop Detection on a port.
Examples of ports: physical, Channelized Bundle over TDM Uplink,
Bridge Ports. | column | Enumeration | .1.3.6.1.4.1.164.6.2.15.5.1.1.20 |
| prtParamActUponLoopDetect This parameter is used to indicate which actions
should be taken in case a loop is detected in the network the port is part of.
Each action is represented by a bit.
Currently defi… | column | OctetString | .1.3.6.1.4.1.164.6.2.15.5.1.1.21 |
| prtParamPSNLayer This object indicates the network layer from which clock is derived. | column | Enumeration | .1.3.6.1.4.1.164.6.2.15.5.1.1.22 |
| prtParamRxSsm This object indicates if Station Clock SSM messages
received will serve as criteria for clock selection. | column | Enumeration | .1.3.6.1.4.1.164.6.2.15.5.1.1.23 |
| prtParamFarEndDevice Programmed Far-End device connected to this port.
This object is relevant for products having multiple DBs.
It will enable configuring offline, the relevant data.
For MP-4100,… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.164.6.2.15.5.1.1.26 |
| prtParamTxClk enable/disable station clock signal output. | column | Enumeration | .1.3.6.1.4.1.164.6.2.15.5.1.1.27 |
| prtParamSdBerThreshold The Signal Degrade Bit Error Rate Threshold.
The negated value of this number is used as the exponent of
10 for computing the threshold value for the Bit Error Rate (BER).
For exa… | column | Unsigned32 | .1.3.6.1.4.1.164.6.2.15.5.1.1.28 |
| prtParamLoopDetectStatus This object shows whether a loop was detected on the current port. | column | Enumeration | .1.3.6.1.4.1.164.6.2.15.5.1.1.29 |
| prtParamClkSrc The source of Transmit Clock.
'loopTiming' or 'loopback' indicates that the recovered receive clock
is used as the transmit clock.
'localTiming' or 'internal' indi… | column | Enumeration | .1.3.6.1.4.1.164.6.2.15.5.1.1.3 |
| prtParamSupportedFeatures This MIB object denotes supported features by the port/interface.
The bit legend must be kept identical to all devices.
Bit 0 = '1' denotes that the port/interface supports ETH OA… | column | OctetString | .1.3.6.1.4.1.164.6.2.15.5.1.1.30 |
| prtParamPortStatus This object shows the status of the current port.
The status is a bit map represented as a sum, therefore,
it can represent multiple failures. When no failure,
the value will be 0… | column | Bits | .1.3.6.1.4.1.164.6.2.15.5.1.1.31 |
| prtParamSsmTx This object defines the SSM transmission from this port.
For SDH/SONET interfaces the object means the following:
disable (2):
- force DNU (DUS) SSM message sending via TDM po… | column | Enumeration | .1.3.6.1.4.1.164.6.2.15.5.1.1.34 |
| prtParamAlias This object is an 'alias' name for the interface as specified by
a network manager, and provides a non-volatile 'handle' for the
interface. | column | OctetString | .1.3.6.1.4.1.164.6.2.15.5.1.1.36 |
| prtParamTxClockInstance This parameter specifies the instance of the clock domain
that is used as transmision clock source. It is equal to the
csmDomainEntry.csmDomainIdx when the CSM is used. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.164.6.2.15.5.1.1.38 |
| prtParamPhantom Power feeding to another device. | column | Enumeration | .1.3.6.1.4.1.164.6.2.15.5.1.1.4 |
| prtParamEntPhysicalIndex The object contains index of the related entPhysicalEntry of
the ENTITY-MIB (RFC 4133) and ENTITY-STATE-MIB (RFC 4268). The
index is built accordign to the rules that are defined … | column | ENTITY-MIBPhysicalIndexOrZero | .1.3.6.1.4.1.164.6.2.15.5.1.1.41 |
| prtParamSsmTxType This object defines the SSM transmission type from this port.. | column | Enumeration | .1.3.6.1.4.1.164.6.2.15.5.1.1.45 |
| prtParamResetStatsCmd on (3) - Reset all statistics of the selected port.
lacp (4) - Reset LACP statistics of the selected port.
l2cp (5) - Reset L2CP statistics of the selected port… | column | Enumeration | .1.3.6.1.4.1.164.6.2.15.5.1.1.5 |
| prtParamLastResetStatsTime The value of MIB II's sysUpTime object at the last time that
prtParamResetStatsCmd was Set to on(3) for this port.
If prtParamResetStatsCmd was never Set to on(3) since last
r… | column | SNMPv2-TCTimeStamp | .1.3.6.1.4.1.164.6.2.15.5.1.1.6 |
| prtParamInterfaceType The interface type of the port, or the frequency used as
clock reference. Clock reference values may be either e1(2)
or t1(3), gps (18) or wave with the specified frequency:
f1544… | column | Enumeration | .1.3.6.1.4.1.164.6.2.15.5.1.1.7 |
| prtParamClearAlarm Setting this attribute to ON, will enforce a clear
operation on the Port Alarms.
Upon completion, the value will automatically change
to off(2). | column | Enumeration | .1.3.6.1.4.1.164.6.2.15.5.1.1.8 |
| prtParamLeds This entry specifies the LEDs status of the port.
Each led is represented by 4 bits where the first 2 bits
(left) specify the status :
(00=NA, 01=OFF, 10=ON, 11=BLINK),
and the n… | column | OctetString | .1.3.6.1.4.1.164.6.2.15.5.1.1.9 |