alarmRelayOutputEnergized
RAD-GEN-MIB ·
.1.3.6.1.4.1.164.6.5.1.10.1.2
Object
column
r/w
Enumeration
This object shows whether the relay transports electricity permanently (energized) or just when the alarm is activated (deEnergized). Default value for critical alarm relay on chassis will be: energized (1). For other severities, the default is: deEnergized (2).
Context
- MIB
- RAD-GEN-MIB
- OID
.1.3.6.1.4.1.164.6.5.1.10.1.2- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- alarmRelayOutputEntry
- Table
- alarmRelayOutputTable
- Siblings
- 3
Syntax
Enumeration
Values & Constraints
Enumerated Values
2 | no |
3 | yes |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| alarmRelayOutputRelayIndex This object is the index of the Alarm Relay.
Values: 1- critical, 2- major, 3- minor according to alarm severity.
For devices with alarms on a slot, the index will be:
(1000*slot … | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.164.6.5.1.10.1.1 |
| alarmRelayOutputOperState This object shows the operational state of the alarm relay. | column | Enumeration | .1.3.6.1.4.1.164.6.5.1.10.1.3 |
| alarmRelayOutputCmd Setting this object to cutOffOn, will suppress the alarm output
as long as it is not triggered again.
Upon completion, the value will automatically change to off(2). | column | Enumeration | .1.3.6.1.4.1.164.6.5.1.10.1.4 |