alarmEventConfigSourceName
RAD-GEN-MIB ·
.1.3.6.1.4.1.164.6.5.1.4.1.7
Object
column
OctetString
ASCII String specifying the name of the source referenced by alarmEventLogSourceId.
The syntax will be similar to CLI.
Example: E1 2/4
where E1 is the source type, 2 is the slot number, 4 is the port number.
The general formula is as follows:
<Source Type> <Slot number>/<Port number>
Source Type is defined in: AlarmEventSourceType.
For types that have 2 words like Serial Bundle, the 1st letter of each word will be capitalized.
For abbreviations we shall have all capitals. Examples: OAM EFM.
CL cards will be: cl-a, cl-b. Main cards will be: main-a, main-b
For SDH over E1 for example with Slots we shall have the same syntax as in CLI.
Example: E1 1/2/3 means: slot=1/port SDH=2/port E1=3
About the slot numbers, these will be the logical numbers of the slots according to
whatever is written on the device panel. For example, if an IO card is in slot IO-5
on the panel, '5' will be displayed for the slot.
Context
- MIB
- RAD-GEN-MIB
- OID
.1.3.6.1.4.1.164.6.5.1.4.1.7- Type
- column
- Access
- readonly
- Status
- current
- Parent
- alarmEventConfigEntry
- Table
- alarmEventConfigTable
- Siblings
- 6
Syntax
OctetString
Values & Constraints
Object Constraints
range: 1-32
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| alarmEventConfigId Alarm and Event ID.
Note: In order to apply a policy for all alarms/events on current source ID
or source type, this object should be set to the following according to
Textual Con… | column | AlarmEventId | .1.3.6.1.4.1.164.6.5.1.4.1.1 |
| alarmEventConfigSourceType This is the Source Type of alarm or event. | column | AlarmEventSourceType | .1.3.6.1.4.1.164.6.5.1.4.1.2 |
| alarmEventConfigSourceId Source ID. This object identifies the specific managed object that causes the alarm.
Note: In order to apply a policy to all Source IDs of the same Source Type,
the fields in the … | column | SourceId | .1.3.6.1.4.1.164.6.5.1.4.1.3 |
| alarmEventConfigSeverity For alarms: values will be one of: critical (3), major (4), minor (5).
For events: value must be warning (6). | column | AlarmSeverity | .1.3.6.1.4.1.164.6.5.1.4.1.4 |
| alarmEventConfigMasking This variable enables alarm and event masking on various reporting means. | column | AlarmEventMasking | .1.3.6.1.4.1.164.6.5.1.4.1.5 |
| alarmEventConfigRowStatus Enable rows creation/deletion.
This is used for managed objects that are dynamically created or removed. | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.164.6.5.1.4.1.6 |