pwCepCfgPktErrorPlayOutValue

PW-CEP-STD-MIB · .1.3.6.1.2.1.200.1.3.1.10

Object

column r/w Unsigned32
This object defines the value played when inbound packets
have over/underflowed the jitter buffer or are missing
for any reason.  This byte pattern is sent (played) on
the SONET path.

Context

MIB
PW-CEP-STD-MIB
OID
.1.3.6.1.2.1.200.1.3.1.10
Type
column
Access
readwrite
Status
current
Parent
pwCepCfgEntry
Groups
1

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PW-CEP-STD-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PW-CEP-STD-MIB::pwCepCfgPktErrorPlayOutValue'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'PW-CEP-STD-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PW-CEP-STD-MIB::pwCepCfgPktErrorPlayOutValue.<pwCepCfgTableIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'PW-CEP-STD-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'PW-CEP-STD-MIB::pwCepCfgPktErrorPlayOutValue'

Syntax

Unsigned32

Values & Constraints

Object Constraints
range: 0-255

Conformance

Member of
Compliance refinements
Write access is not required for implementations
that support only a single predefined value.
Write access is not required.