referenceSec

PT-RADIOLINK-MIB · .1.3.6.1.4.1.193.223.2.7.1.1.33

Object

column r/w Enumeration
Each modulation is compliant to a Reference Spectrum Efficiency Class (RSEC). 
When running Adaptive Coding/Modulation, one SEC has to be selected for all the coding/modulations between selectedMinACM and selectedMaxACM.
This parameter is called Reference SEC. This setting will affect availableMaxOutputPower, in order to fulfill spectrum requirements.
Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination.

Context

MIB
PT-RADIOLINK-MIB
OID
.1.3.6.1.4.1.193.223.2.7.1.1.33
Type
column
Access
readwrite
Status
current
Parent
ctEntry
Groups
1

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PT-RADIOLINK-MIB' -M '/opt/observium/mibs/ericsson:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PT-RADIOLINK-MIB::referenceSec'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'PT-RADIOLINK-MIB' -M '/opt/observium/mibs/ericsson:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PT-RADIOLINK-MIB::referenceSec.<index>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'PT-RADIOLINK-MIB' -M '/opt/observium/mibs/ericsson:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'PT-RADIOLINK-MIB::referenceSec'

Syntax

Enumeration

Values & Constraints

Enumerated Values
1noAvailable
2sec2
4sec4L
5sec4H
7sec5B
9sec6B
10sec5LB
11sec5HB
12sec6LB
13sec6HB
14sec7B
15unknown