snmpVoltage

OBS ✓
PPM-IGNIS-MIB · .1.3.6.1.4.1.31225.1.1.1.21

Object

scalar mVInteger32
ViaLiteHD backplane voltage reading, measured in millivolts. Nominal value 12000mV.
Trap thresholds set by lowVoltageThreshold & highVoltageThreshold (ignisSystem.28 & .29).
Observium directly uses this object
This object is referenced by an Observium discovery or polling workflow.
Used in: Sensors
Explore Observium network monitoring

Context

MIB
PPM-IGNIS-MIB
OID
.1.3.6.1.4.1.31225.1.1.1.21
Type
scalar
Access
readonly
Status
current
Units
mV
Parent
ignisSystem

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'PPM-IGNIS-MIB' -M '/opt/observium/mibs/vialite:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PPM-IGNIS-MIB::snmpVoltage.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'PPM-IGNIS-MIB' -M '/opt/observium/mibs/vialite:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'PPM-IGNIS-MIB::snmpVoltage'

Syntax

Source
SNMPv2-SMIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647