snmpVoltage
OBS ✓
PPM-IGNIS-MIB ·
.1.3.6.1.4.1.31225.1.1.1.21
Object
scalar mVInteger32
ViaLiteHD backplane voltage reading, measured in millivolts. Nominal value 12000mV. Trap thresholds set by lowVoltageThreshold & highVoltageThreshold (ignisSystem.28 & .29).
Observium directly uses this object
This object is referenced by an Observium discovery or polling workflow.
Used in:
Sensors
Explore Observium network monitoring
Context
- MIB
- PPM-IGNIS-MIB
- OID
.1.3.6.1.4.1.31225.1.1.1.21- Type
- scalar
- Access
- readonly
- Status
- current
- Units
- mV
- Parent
- ignisSystem
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'PPM-IGNIS-MIB' -M '/opt/observium/mibs/vialite:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PPM-IGNIS-MIB::snmpVoltage.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'PPM-IGNIS-MIB' -M '/opt/observium/mibs/vialite:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'PPM-IGNIS-MIB::snmpVoltage'
Syntax
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647