modAmpGainAlThCtrl

PPM-IGNIS-MIB · .1.3.6.1.4.1.31225.1.1.4.1.1.334

Object

column r/w x 10mdBInteger32
Amplifier Gain warning threshold, measured in 10mdB.
This threshold is measured from the alarm thresholds (typically a low threshold of 15dB, and a high threshold of 30dB),
i.e, if the Alarm threshold is 10dB, and this warning threshold is set at 2dB, the warning shall be triggered
if the level reaches 8dB (10dB-2dB).

Context

MIB
PPM-IGNIS-MIB
OID
.1.3.6.1.4.1.31225.1.1.4.1.1.334
Type
column
Access
readwrite
Status
current
Units
x 10mdB
Parent
slotsEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PPM-IGNIS-MIB' -M '/opt/observium/mibs/vialite:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PPM-IGNIS-MIB::modAmpGainAlThCtrl'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'PPM-IGNIS-MIB' -M '/opt/observium/mibs/vialite:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PPM-IGNIS-MIB::modAmpGainAlThCtrl.<index>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'PPM-IGNIS-MIB' -M '/opt/observium/mibs/vialite:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'PPM-IGNIS-MIB::modAmpGainAlThCtrl'

Syntax

x 10mdBInteger32
Source
SNMPv2-SMIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647