pnniIfNodeIndex

PNNI-MIB · .1.3.6.1.4.1.353.5.4.1.1.8.1.1

Object

column r/w Integer32
Identifies the node within the switching system that the
interface is directly attached to.  The value zero is not 
a valid value.

Context

MIB
PNNI-MIB
OID
.1.3.6.1.4.1.353.5.4.1.1.8.1.1
Type
column
Access
readwrite
Status
current
Parent
pnniIfEntry
Groups
1

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PNNI-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PNNI-MIB::pnniIfNodeIndex'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'PNNI-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PNNI-MIB::pnniIfNodeIndex.<ifIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'PNNI-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'PNNI-MIB::pnniIfNodeIndex'

Syntax

Integer32

Values & Constraints

Object Constraints
range: 1-65535

Conformance

Member of
Compliance refinements
Write access to the pnniIfNodeIndex object is optional. It
only applies when there can be multiple lowest-level nodes
in the switching system.