pktcSigPulseSignalRepeatCount
PKTC-IETF-SIG-MIB ·
.1.3.6.1.2.1.169.1.1.20.1.6
Object
column
r/w
Unsigned32
This object specifies how many times to repeat a pulse.
This object is not used by the enableMeterPulse signal
type, and in that case, the value is irrelevant. The
following table defines the default values and the valid
ranges for this object, depending on the signal type:
pktcSigPulseSignaltype Default Range
initialRing 1 1-5
pulseLoopClose 1 1-50
pulseLoopOpen 1 1-50
enableMeterPulse (any value)(but not used)
meterPulseBurst 1 1-50
pulseNoBattery 1 1-50
pulseNormalPolarity 1 1-50
pulseReducedBattery 1 1-50
pulseReversePolarity 1 1-50
An attempt to set this object to a value that does not
fall within the range for the specific
signal type will result in an 'inconsistentValue' error.
Context
- MIB
- PKTC-IETF-SIG-MIB
- OID
.1.3.6.1.2.1.169.1.1.20.1.6- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- pktcSigPulseSignalEntry
- Table
- pktcSigPulseSignalTable
- Siblings
- 5
Syntax
Unsigned32
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pktcSigPulseSignalType There are nine types of international pulse signals. These
signals are defined as follows:
initial ring
pulse loop close
pulse loop open
enable meter pulse
meter pulse burst
puls… | column | Enumeration | .1.3.6.1.2.1.169.1.1.20.1.1 |
| pktcSigPulseSignalFrequency This object is only applicable to the initialRing,
enableMeterPulse, and meterPulseBurst signal types. This
object identifies the frequency of the generated signal.
The following… | column | Enumeration | .1.3.6.1.2.1.169.1.1.20.1.2 |
| pktcSigPulseSignalDbLevel This object is only applicable to the enableMeterPulse and
meterPulseBurst signal types. This is the decibel level
for each frequency at which tones could be generated at
the a a… | column | 1/10 of a dBm Integer32 | .1.3.6.1.2.1.169.1.1.20.1.3 |
| pktcSigPulseSignalDuration This object specifies the pulse duration for each
signal type. In addition, the MTA must accept the values
in the incremental steps specific for each signal type.
The following t… | column | Milliseconds Unsigned32 | .1.3.6.1.2.1.169.1.1.20.1.4 |
| pktcSigPulseSignalPulseInterval This object specifies the repeat interval, or the period,
for each signal type. In addition, the MTA must accept
the values in the incremental steps specific for each
signal type… | column | Milliseconds Unsigned32 | .1.3.6.1.2.1.169.1.1.20.1.5 |